News
DN
NoodleNews
ANALYSIS
30 JUL 2026
Science · water treatment

A new method removes 99.99% of PFOS from water. It releases 35% of the fluorine.

Two German studies report genuine breakdown of a “forever chemical”, not just capture. But the measure that shows carbon–fluorine bonds actually breaking lags far behind the removal figure — and in the best-performing runs, most of the fluorine could not be traced at all.

35%
of the fluorine in the treated PFOS was recovered as fluoride — the direct evidence of bonds breaking
99.99%
of the PFOS was cleared from the water in that same run
50%
of the starting fluorine could be accounted for, at best, in the gas-dispersed runs
What the data shows

Two measures, and only one of them made the headlines

Researchers at the Helmholtz-Zentrum Dresden-Rossendorf published two papers this year on breaking down perfluorooctane sulfonate, or PFOS — among the most studied of the “forever chemicals”, and one used for decades in firefighting foams, textiles and non-stick coatings.1 One uses cold atmospheric plasma with air bubbled through the water.1 The other forces water through a narrow orifice at 48 bar until vapour bubbles form and collapse.2 Both work. Neither is a filter.

The nickname is earned by a single feature of the chemistry. PFOS is a chain of eight carbon atoms sheathed in fluorine, and the bond between carbon and fluorine is the strongest in organic chemistry — strong enough that neither weathering, nor bacteria, nor conventional water treatment can break it.1 That is why the compounds accumulate: not because they are produced in vast quantities, but because almost nothing takes them apart again.

That distinction is the point. Activated carbon, ion-exchange resin and high-pressure membranes — the established options — strip more than 99% of PFOS out of drinking water.3 They do it by moving the molecule onto a solid, intact. The carbon then becomes contaminated waste, usually bound for an incinerator.1 Nothing is destroyed; the problem is relocated.

So the papers report two different numbers, and the distance between them is the story. Degradation is how much PFOS is left: the instrument searches for that one molecule and reports what it can no longer find. Defluorination is how much fluorine has come away as fluoride — a simple inorganic ion that is no longer part of any fluorinated molecule at all. Only the second is direct evidence that a carbon–fluorine bond actually broke.

A rough analogy: measuring plastic pollution by counting intact bottles. Smash the bottles and the count falls to zero, but the plastic is all still present as fragments. Degradation is the bottle count. Defluorination is the measure that tells you material genuinely left the system — and in these experiments the two numbers are a long way apart.

Exhibit 01
Clearing PFOS from water is not the same as breaking it apart
Source: Best reported result for each approach. Plasma and cavitation figures as printed in the two 2026 papers, both for PFOS in tap water, both expressed as a share of the initial PFOS.12 Filtration removal is the US EPA’s reported maximum for granular activated carbon; its defluorination is zero by mechanism, since adsorption does not cleave bonds.3 Read each pair together: the grey bar is how much PFOS left the water, the blue bar how much of its fluorine was actually freed. Not a controlled head-to-head — the three use different reactors and durations.
Key finding. In its best run, the plasma method cleared 99.99% of the PFOS from the water and recovered 35% of that PFOS’s fluorine as fluoride.1 Both are measured figures from the same experiment.
Inside one run

The removal curve races ahead; the fluorine curve does not follow

A single 20-minute plasma run makes the divergence plain. PFOS collapses — 92% gone in five minutes, 99% in ten — a half-life of 1.6 minutes, meaning half of whatever is present clears every minute and a half.1 Fluoride release does not track it: 33% at five minutes, 27% at ten, 35% at twenty.

Exhibit 02
Gas-dispersed plasma, PFOS at 5 mg per litre in tap water
Source: Kumar et al., Scientific Reports (2026), 10 mL sample, 12 W input, air at 0.1 L/min. Both series are measured, as percentages of the initial PFOS. The dip in fluoride at ten minutes is in the published data, not smoothing — the authors attribute such fluctuations to fluoride adsorbing onto reactor surfaces and to fluorinated intermediates escaping into gas or foam.1

The authors are explicit that the parent molecule is not simply vanishing. They detect a chain of shorter perfluorinated acids forming as PFOS breaks down — PFOA first, then progressively shorter.1 Those are still PFAS, and the shorter ones adsorb less readily than the compound they came from.4

The counterintuitive part

The weaker method converts more of what it breaks

Cavitation looks far worse on the headline measure: 37% degradation against the plasma’s 99.99%.2 But ask a different question — of the PFOS each method did break down, how much was taken apart all the way? — and the ranking inverts. Cavitation’s 20% defluorination against 37% degradation works out at 54%. The plasma’s 35 against 99.99 works out at 35%. Per unit of PFOS destroyed, the slower method freed roughly one and a half times as much fluorine.

A second pattern in the plasma paper runs the same way. Bubbling air through the water is what lifts degradation from 76% to 99.99%. It also makes the fluorine accounting markedly worse: without gas dispersion the authors recover 68–106% of the fluorine they started with, and with it, 31–50%.1 The configuration that produces the impressive removal figure is the one that loses track of most of the fluorine.

One reading — interpretation, not a finding either paper states — is that this is the same effect twice: fast removal of the parent compound outruns the slower work of cleaving C–F bonds, leaving more material in intermediate states nobody has measured. A peer-reviewed review of the wider field this year, unconnected to the Dresden group, names incomplete defluorination as the central unsolved bottleneck.6 Consistent with the pattern — not proof of it.

The Dresden group’s own stated next step is to combine the two processes, on the expectation that plasma’s reactive species and cavitation’s collapsing bubbles will do together what neither manages alone.7 That work has not been published.

What we don’t know

Where most of the fluorine went. In the gas-dispersed runs, between 50% and 69% of the fluorine present at the start could not be found at the end — not as fluoride, not as any of the intermediates the team screened for. The authors list unidentified fluorinated products, escape into the gas or foam phase, and adsorption onto reactor walls as possibilities, and state that the fate is unresolved.1 This is disclosed in the paper, not uncovered here.

Whether either method scales. Both were run on laboratory volumes — 10 to 40 millilitres in the plasma work — and at PFOS concentrations of 1 to 5 milligrams per litre. UK drinking water is regulated against a guideline of 0.1 micrograms per litre for the sum of 48 PFAS.5 The experiments ran at 1 to 5 milligrams per litre — ten thousand to fifty thousand times more concentrated than that guideline. Dilute solutions are harder to treat, not easier, because the reactive species have to find far fewer target molecules.1

What the intermediates do. The shorter-chain acids that form during treatment are quantified, but their toxicity and persistence are not addressed by either study. Ultra-short-chain products such as trifluoroacetic acid were looked for and not detected — which the authors note may mean they were absent, or below the detection threshold.1

By the numbers
40%
Highest defluorination in any run in either paper — and it came from the plasma without gas dispersion1
1.6min
PFOS half-life under gas-dispersed plasma1
39
kWh per cubic metre to cut PFOS tenfold by plasma — against roughly 1,312 kWh/m³ to incinerate the same water1
0.1µg/L
UK guideline for the sum of 48 PFAS in drinking water5
Caveat. The strongest objection to reading these results as a breakthrough is that a low fluorine recovery does not prove fluorine is missing — it may simply be unmeasured. The plasma team screened for a defined list of transformation products by LC–MS; anything outside that list is invisible to the method, so the 31–50% recovery is a floor on what was destroyed, not a ceiling. Equally, the reverse objection holds: nothing in these papers rules out that the unrecovered fraction is intact fluorinated material that simply moved somewhere else. Both readings are open, and neither study can settle it.
Method. Both new figures are as printed in the two primary papers; no figure here is re-derived from a chart. Degradation is the fall in measured parent-compound concentration (PFOS) by LC–MS. Defluorination is fluoride ion released, measured photometrically by the SPADNS method and expressed by both papers as a percentage of the fluorine in the initial PFOS — so the two measures share a base and are directly comparable.12 Ratios of defluorination to degradation (35% and 54%) were computed in Node from those printed values and re-checked. The filtration comparator is the US EPA’s reported maximum removal efficiency for PFOA and PFOS by granular activated carbon; its zero defluorination is a mechanical fact of adsorption, not a measurement.3 Plasma and cavitation runs used different reactors, volumes and durations, so Exhibit 01 compares each method’s own best reported result, not a controlled head-to-head. No projection or model is used anywhere in this piece.
Sources. Numbered, highest tier first; each inline citation points here.
  1. T1Kumar, A., Huaccallo-Aguilar, Y., Kryk, H., Hampel, U. & Reinecke, S. F. “Enhanced degradation and defluorination of perfluorooctane sulfonate (PFOS) in tap water using gas-dispersed cold atmospheric plasma.” Scientific Reports 16, 18363 (13 June 2026). Peer-reviewed, open access. doi:10.1038/s41598-026-57490-6. Retrieved 29 July 2026.
  2. T1Kumar, A., Georgi, A., Huaccallo-Aguilar, Y., Meier, M., Kryk, H., Reinecke, S. F. & Hampel, U. “Degradation and defluorination of perfluorooctane sulfonate (PFOS) forever chemical in water using hydrodynamic cavitation treatment.” Chemical Engineering Journal Advances 25, 101046 (2026). Peer-reviewed. doi:10.1016/j.ceja.2026.101046. Figures taken from the published abstract and highlights; full text not retrieved. Retrieved 29 July 2026.
  3. T1US Environmental Protection Agency. Best Available Technologies and Small System Compliance Technologies for PFAS in Drinking Water (April 2024) — maximum GAC and membrane removal efficiencies for PFOA and PFOS above 99%. epa.gov. Retrieved 29 July 2026.
  4. T1US Environmental Protection Agency, Science Matters. “Reducing PFAS in Drinking Water with Treatment Technologies” — activated carbon, ion exchange and high-pressure membranes as the established options; short-chain PFAS adsorb less readily. epa.gov. Retrieved 29 July 2026.
  5. T1UK Parliament, written question 49285 (answered 2025) — Drinking Water Inspectorate guideline value of 0.1 µg/L, with water companies monitoring 48 individual PFAS and reporting exceedances as a water quality event. questions-statements.parliament.uk. Retrieved 29 July 2026.
  6. T1“Advances in electrochemical technologies for PFAS destruction.” Chemical Science (2026), doi:10.1039/D5SC09459C — peer-reviewed review identifying incomplete defluorination and mass-transfer limits as the field-wide bottleneck, independent of the Dresden work. rsc.org. Retrieved 29 July 2026.
  7. T2Helmholtz-Zentrum Dresden-Rossendorf, press statement via EurekAlert, July 2026 — the group’s stated intention to combine the two processes; analyses supporting fluoride release run with the Helmholtz Centre for Environmental Research. eurekalert.org. Retrieved 29 July 2026.
Corrections. None. Material corrections will be logged here with date.
Figures to 30 Jul 2026. Noodle News · v1.1 · pfas-destruction-fluorine-gap.